Skip to main navigation Skip to main content Skip to page footer

AKCP securityProbe5ES-X20: Professional leak monitoring for server rooms and data centres

AKCP securityProbe5ES-X20

The AKCP securityProbe5ES-X20 is a highly advanced monitoring solution specifically designed for critical IT environments. In addition to classic server room monitoring for detecting temperature, humidity, power failures, and smoke, the system places a particular focus on reliable protection against water ingress and leaks. Especially in the raised floors of modern data centers, water is considered one of the greatest risks, as even small leaks can quickly lead to short circuits and large-scale outages.

With its 20 additional dry contact inputs and eight RJ-45 sensor ports, the securityProbe5ES-X20 offers maximum flexibility to integrate water leakage sensors, leak detection ropes, and external systems such as pumps, fire detectors, or air conditioning units. This creates a comprehensive protection concept against physical and environmental threats.

Water leaks as a critical risk for IT infrastructures

Causes of water ingress in data centers are manifold:

  • Overflowing condensate tanks from air conditioning systems
  • Defective pipes in cooling water systems
  • Damage to sprinkler systems
  • Undetected pipe bursts in buildings

The consequences range from data loss to hours of downtime and enormous financial damage. That is why operators of data centers and critical infrastructures increasingly rely on systems such as the AKCP securityProbe5ES-X20 with integrated leak monitoring.

Intelligent sensor integration for leak detection

Various sensors can be connected via the eight RJ-45 sensor ports:

  • Spot water sensors – ideal for single critical areas such as under cooling units or at cable penetrations.
  • Leak detection ropes – cover large areas under raised floors and pinpoint the exact point of water ingress.
  • Combined temperature and humidity sensors – detect rising humidity as an early warning.

The plug-and-play function automatically detects connected water sensors, configures them independently, and immediately displays the readings in the web interface.

Practical examples of water protection

Case 1: Raised floor in the data center

A financial institution installed a leak detection rope in the raised floor. Long before serious damage occurred, the securityProbe5ES-X20 detected a leak caused by a defective cooling pipe and displayed the location on the floor plan. The rapid localization significantly reduced maintenance times.

Case 2: Server room air conditioning

An insurance company deployed spot water sensors directly under condensate pipes. When condensate leaked, an alarm was immediately triggered via e-mail, SMS, and SNMP. At the same time, the affected air conditioning unit was shut down via dry contacts.

Case 3: Industrial environment

In a production hall, the securityProbe5ES-X20 was combined with water leakage sensors and a connected alarm system. In the event of a leak, the system not only activated alarms but also control valves to shut down water circuits.

20 dry contacts for leak integration

The extended 20 dry contacts of the X20 version make the system particularly powerful in water protection:

  • Integration of external pumps or shut-off valves
  • Coupling with fire and water detection systems
  • Triggering relay controls in the event of leaks
  • Centralizing various alarm circuits

The dry contacts are opto-isolated and support voltages up to 40V DC, making integration into industrial environments particularly easy.

Alarm notification in the event of water ingress

As soon as a water leakage sensor or detection rope is triggered, extensive alarms are available:

  • E-mail alerts to defined distribution lists
  • SMS/voice alarms via 3G/4G modules
  • SNMP traps to systems such as Nagios, PRTG, or SolarWinds
  • Individual escalation plans with acknowledgment requirements

This ensures that operators know in real time when water enters the server room – and can respond immediately.

Scalability for large-scale monitoring

The securityProbe5ES-X20 supports up to 500 sensors through the use of expansion modules such as E-Sensor8 or E-opto16. This enables reliable monitoring of even large building structures with multiple floors. Cascading options of up to 300 meters are available for long cable routes.

The AKCP securityProbe5ES-X20 offers far more than standard environmental monitoring. With its 20 dry contacts, eight RJ45 sensor ports, and integration of water leakage sensors as well as leak detection ropes, it becomes a comprehensive platform for leak monitoring and water protection. Whether in data centers, server rooms, or industrial parks – this solution minimizes the risk of costly water damage.

Summary

Can the 5ES-X20 locate leaks in raised floors?

Yes, with leak detection ropes the system detects and pinpoints the exact location of water ingress.

How is alarm notification handled in the event of water ingress?

Via e-mail, SMS, SNMP traps, or voice alarms – optionally with acknowledgment to ensure no alarm is ignored.

Can external systems such as pumps or air conditioning units be controlled?

Yes, through the 20 dry contacts, relays, pumps, and other external systems can be controlled automatically.

AKCP securityProbe-5ES

AKCP securityProbe-5ES
The AKCP securityProbe-5ES provides the perfect solution for companies seeking professional IT infrastructure monitoring and protection against costly outages. In an era where digitization and continuous availability are critical for business, this advanced monitoring system offers comprehensive protection against environmental impacts and security risks.

Featuring eight RJ-45 sensor ports and two RJ-45 expansion ports with 115.2 kBit/s data transfer rate, the architecture supports simultaneous use of expansion ports and Modbus RS485 interface. The integrated 10/100 Mbps Ethernet interface ensures reliable network connectivity with an additional USB 2.0 modem port for expanded communication options.

SEC-5ES (Technical data AKCP manufacturer specifications)

ParameterDetails
DimensionsSize: 8.5″ x 5.43″ x 1.80″
Weight: 1 kg
Expansion Ports2x RJ-45 expansion ports
115.2 Kbps data transfer rate
Simultaneous functionality between expansion ports & RS485 port threshold status
Mounting1U rack-mount standard
Rack-mount brackets included
Compatible with AKCP DIN- and rack-mount rails
Power SupplyExternal power supply 7.0–9 VDC, 3A
Input voltage/current: 100–240V AC, 1A
Optional: DCW – external ±40~60V DC input
Power ConsumptionTypical 5.025 W, 0.67 A
Status IndicatorsLED indicator for power supply
LED for network connection
LED for sensor status and threshold exceedance
ComponentsHighly integrated low-power SMT technology for reliability
CPU: AKCP i.MX25 processor
128 MB on-board NAND flash
SD slot up to 16 GB
Operating EnvironmentTemperature: -35 °C to +55 °C
Humidity: 20 % to 80 % (non-condensing)
MTBF: 400,000 hours
ConnectivityEthernet 10/100 Mbps
Optional: internal 3G/4G modem
Inputs8x RJ-45 sensor ports
2x RJ-45 expansion ports
1x USB 2.0 modem port
Audio In (Analog) 2.5 mm jack
Internal microphone
RS485 (2-pin terminal block, Modbus)
OutputsConfigurable signals (0VDC/5VDC) on all 8 sensor ports
Internal speaker
External speaker (2.5 mm jack, analog)
Mic out, 2.5 mm jack (for modem)
Expansion Modules8-port intelligent sensors module (E-Sensor8)
16-port dry contact module (E-opto16, max. 500 sensors)
Cabinet Control Unit (up to 25 per chain)
Expandable up to 300 meters
Modules daisy-chainable

This website uses cookies

This website uses cookies to improve user experience. By using our website you consent to all cookies in accordance with our Cookie Policy.

Essential cookies enable basic functions and are necessary for the website to function properly.
Statistics cookies collect information anonymously. This information helps us to understand how our visitors use our website.
Marketing cookies are used by third parties or publishers to display personalized advertisements. They do this by tracking visitors across websites.