Didactum Monitoring System 50T Bundle – Protection against water leakage and water ingress
Didactum Monitoring System 50T Bundle
Water damage is among the most dangerous risks in small server rooms, IT environments, and technical installations. Even small amounts of leaking water can destroy sensitive hardware and cause significant downtime costs. The Didactum Monitoring System 50T Bundle provides companies and organizations with an immediately deployable complete solution for water leakage monitoring and protection against water intrusion. The set includes the Monitoring System 50T along with a temperature sensor, a humidity sensor, a smoke detector, and a water sensor for a comprehensive security concept.
As an IP-based monitoring system, the 50T not only monitors temperature and humidity but also delivers reliable water protection for IT infrastructures, facilities, and smart home environments. All sensors are evaluated in real time and threshold breaches are detected immediately. As soon as a leakage sensor detects moisture in the server room, the water damage alarm is automatically issued via email, SMS, or SNMP trap. This ensures a quick response to prevent more extensive damage and failures.
With scalability of up to 100 sensors and 700 configurable elements, the bundle suits a variety of use cases—from data center monitoring to building automation. The web-based interface allows individual configuration of sensors, thresholds, triggers, and alarm paths. Integration into popular network tools like Nagios, Zabbix, or PRTG makes the solution universally usable and easy to integrate into existing IT infrastructures.
The bundle combines all essential factors of infrastructure risk management: temperature control, humidity safety, smoke and fire early detection, and especially prevention of water leakage and intrusion. Thus, the 50T is a cost-effective, professional monitoring system for small IT environments, smart buildings, and technical controls.
Components of the 50T Bundle
Monitoring System 50T
The core of the bundle is the Didactum Monitoring System 50T. It offers 100 sensor connections, real-time logging, and an intuitive web interface. Serving as a remote monitoring system for critical infrastructures, it functions as both a security and energy management solution. Alarms via email, SNMP traps, or SMS provide immediate notifications when critical conditions develop.
Temperature Sensor
With a measuring range from -40 °C to +100 °C and accuracy of ±0.4 °C, the temperature sensor enables precise climate control for server rooms, storage areas, or production facilities. It is auto-recognized via the AutoSense function and ideal for evaluating climate systems and preventing overheating.
Humidity Sensor
The humidity sensor reliably measures critical air humidity parameters. With ±3 % RH accuracy, it prevents risks such as condensation or mold and supports dew point and frost point calculations, securing water damage prevention caused by climatic moisture.
Smoke Sensor
The smoke detector provides early fire detection in data centers, industrial sites, and buildings. It triggers coordination and alarm chains upon detecting smoke particles. Combined with temperature monitoring, it forms a highly sensitive fire prevention system with SNMP integration.
Water Sensor
The water sensor enables real-time leak detection. It detects liquid using robust, corrosion-resistant contacts. In combination with relay outputs, automatic reactions such as closing valves or switching on emergency pumps can be triggered in case of a water alarm. Thus, it serves as the central element for water leakage monitoring.
Applications
- Small server rooms and data centers with a focus on water protection
- IT environments requiring automated alarm chains
- Industrial and production facilities to secure critical infrastructure
- Smart home monitoring with IP-based control
- Building technology and facility management, e.g., HVAC and UPS monitoring
Benefits of the Didactum Monitoring Bundle 50T
- Reliable detection of water intrusion and leaks
- Cost-efficient – complete solution with four sensors included
- Real-time alarms for critical conditions
- Integration into network management software and smart home systems
- Web-based operation, data logger, and scalability
- Made in EU – German-language support
Summary
Can the bundle monitor multiple types of risks simultaneously?
Yes, the 50T bundle not only monitors water leakage but also temperature, humidity, and smoke development, enabling comprehensive monitoring.
How does the system alert a water alarm?
Upon detecting water, the system sends real-time alerts via email, SMS (optional), or SNMP traps. Additionally, acoustic and visual alarms can be triggered.
Is the system suitable for use in smart homes?
Yes, thanks to IP technology and control options via potential-free contacts, the system can be easily integrated into smart home structures.
Basic Protection Monitoring System 50T
DI19005 (Technical data AKCP manufacturer specifications)
Technical Specifications Didactum Monitoring System 50
| Parameter | Details |
|---|---|
| Device Management | Web, SNMP |
| Sensor Access | Three-level login |
| LAN | Ethernet 100 Mbit |
| Operating System | Linux v.6.2 |
| Interface | Any browser |
| RAM | 128 MB |
| CPU Speed | 600 MHz |
| CPU Cores | 2 |
| Clock | Built-in clock |
| Timer | Built-in watchdog |
| Max. Number of Sensors | 100 (physical sensors, dry contacts, relays) |
| Max. Number of Elements | 700 (notifications, triggers, timers, logic, sensors, etc.) |
| LTE Gateway Mode | No |
| LTE Access Mode | No |
| Network Protocols | DHCP, HTTP, HTTPS, SNMP, SMTP, FTP, Syslog, TLS |
| Modbus RTU | No |
| Modbus TCP | Yes |
| VPN Secure Transmission | No |
| Power Input (230V AC) | No |
| Power Input (24–48V DC) | No |
| Power Input (12V DC) | Input |
| Min. Power Consumption | 1 W |
| Max. Power Consumption | 6 W |
| Analog Port | 4 built-in ports (6P6C for analog sensor connection) |
| CAN Port | 1 port, max 10 devices |
| Dry Contact Inputs | 2 |
| Relay Outputs | 2 x 12 V, 0.25 A |
| USB Cameras | 1 |
| IP Cameras | up to 4 |
| Operating Temperature | -10 to +70 °C |
| Storage Temperature | -25 to +85 °C |
| Operating Humidity | 0 to 90 % (non-condensing) |
| Installation | Desktop |
| Enclosure Material | Plastic |
| Dimensions (L x W x H) | 150 x 29 x 100 mm |
| Weight | 0.5 kg |
Technical Specifications Didactum Temperature Sensor
| Parameter | Details |
|---|---|
| Sensor Type | Analog sensor |
| Measures | Temperature |
| Accuracy | ±0.5 °C at room temperature |
| Daisy Chain | No |
| Cable Length | 2 m |
| Power Consumption | 60 mW |
| Operating Temperature | Optimal range: -10 to +80 °C |
| Operating Humidity | 0 to 95 % |
| Mounting Options | Table device, indoor, rack mounting, wall mounting |
| Max Distance to Unit | 100 m |
Technical Specifications Didactum Humidity Sensor
| Parameter | Details |
|---|---|
| Sensor Type | Analog sensor |
| Measures | Relative humidity |
| Accuracy | 3 % RH |
| Daisy Chain | No |
| Cable Length | RJ11 6P4C 2 m telephone cable included |
| Power Consumption | 60 mW |
| Operating Temperature | Optimal range: -10 to +80 °C |
| Operating Humidity | 0 to 95 % indoors |
| Mounting Options | Table device, indoor, rack mounting, wall mounting |
| Max Distance to Unit | 50 m |
Technical Specifications Didactum Smoke Sensor
| Parameter | Details |
|---|---|
| Device Type | Analog sensor |
| Sensor Type | Photoelectric |
| Measures | Smoke, fire |
| Daisy Chain | Yes, up to 10 sensors in one chain. The system shows all sensors in a chain as a single element. Triggering any sensor in the chain activates the element in the web interface. |
| Cable Length | RJ11 / RJ12 6P4C, 2 m telephone cable included |
| Power Consumption | 100 mW |
| Operating Temperature | Optimal: -10 to +55 °C – Extended: -10 to +80 °C |
| Storage Temperature | -10 to +55 °C |
| Operating Humidity | 5 to 95 % (non-condensing) |
| Storage Humidity | 5 to 95 % |
| Average Lifetime | >= 10 years |
| LED Display | Red LED |
| Mounting Options | Ceiling mounted |
| Max Distance to Unit | 150 m from unit or extension module |
Technical Specifications Didactum Water Sensor
| Parameter | Details |
|---|---|
| Sensor Type | Analog sensor |
| Detection Method | Capacitive |
| Accuracy | 3 % RH |
| Daisy Chain | No |
| Description | Sensor has two RJ connectors. RJ 6P4 connects to the analog input of the Didactum monitoring system. RJ 4P2 connects to two poles of the sensor. |
| Dimensions | 60 × 18 × 18 mm |
| Inputs | 2-wire (WDC cable) |
| Outputs | RJ11 / RJ12 |
| Operating Temperature | -10 to +80 °C |
| Operating Humidity | 5 to 95 % (non-condensing) |
| Power Consumption | 60 mW |
| Mounting | Mounting bracket included |
| Max Distance | 100 m from monitoring system |
| Response Time | 15 seconds |
| Recovery Time | Depends on drying speed |