Skip to main navigation Skip to main content Skip to page footer

Didactum Monitoring System 50T Bundle – Protection against water leakage and water ingress

Didactum Monitoring System 50T Bundle

Water damage is among the most dangerous risks in small server rooms, IT environments, and technical installations. Even small amounts of leaking water can destroy sensitive hardware and cause significant downtime costs. The Didactum Monitoring System 50T Bundle provides companies and organizations with an immediately deployable complete solution for water leakage monitoring and protection against water intrusion. The set includes the Monitoring System 50T along with a temperature sensor, a humidity sensor, a smoke detector, and a water sensor for a comprehensive security concept.

As an IP-based monitoring system, the 50T not only monitors temperature and humidity but also delivers reliable water protection for IT infrastructures, facilities, and smart home environments. All sensors are evaluated in real time and threshold breaches are detected immediately. As soon as a leakage sensor detects moisture in the server room, the water damage alarm is automatically issued via email, SMS, or SNMP trap. This ensures a quick response to prevent more extensive damage and failures.

With scalability of up to 100 sensors and 700 configurable elements, the bundle suits a variety of use cases—from data center monitoring to building automation. The web-based interface allows individual configuration of sensors, thresholds, triggers, and alarm paths. Integration into popular network tools like Nagios, Zabbix, or PRTG makes the solution universally usable and easy to integrate into existing IT infrastructures.

The bundle combines all essential factors of infrastructure risk management: temperature control, humidity safety, smoke and fire early detection, and especially prevention of water leakage and intrusion. Thus, the 50T is a cost-effective, professional monitoring system for small IT environments, smart buildings, and technical controls.

Components of the 50T Bundle

Monitoring System 50T

The core of the bundle is the Didactum Monitoring System 50T. It offers 100 sensor connections, real-time logging, and an intuitive web interface. Serving as a remote monitoring system for critical infrastructures, it functions as both a security and energy management solution. Alarms via email, SNMP traps, or SMS provide immediate notifications when critical conditions develop.

Temperature Sensor

With a measuring range from -40 °C to +100 °C and accuracy of ±0.4 °C, the temperature sensor enables precise climate control for server rooms, storage areas, or production facilities. It is auto-recognized via the AutoSense function and ideal for evaluating climate systems and preventing overheating.

Humidity Sensor

The humidity sensor reliably measures critical air humidity parameters. With ±3 % RH accuracy, it prevents risks such as condensation or mold and supports dew point and frost point calculations, securing water damage prevention caused by climatic moisture.

Smoke Sensor

The smoke detector provides early fire detection in data centers, industrial sites, and buildings. It triggers coordination and alarm chains upon detecting smoke particles. Combined with temperature monitoring, it forms a highly sensitive fire prevention system with SNMP integration.

Water Sensor

The water sensor enables real-time leak detection. It detects liquid using robust, corrosion-resistant contacts. In combination with relay outputs, automatic reactions such as closing valves or switching on emergency pumps can be triggered in case of a water alarm. Thus, it serves as the central element for water leakage monitoring.

Applications

  • Small server rooms and data centers with a focus on water protection
  • IT environments requiring automated alarm chains
  • Industrial and production facilities to secure critical infrastructure
  • Smart home monitoring with IP-based control
  • Building technology and facility management, e.g., HVAC and UPS monitoring

Benefits of the Didactum Monitoring Bundle 50T

  • Reliable detection of water intrusion and leaks
  • Cost-efficient – complete solution with four sensors included
  • Real-time alarms for critical conditions
  • Integration into network management software and smart home systems
  • Web-based operation, data logger, and scalability
  • Made in EU – German-language support

Summary

Can the bundle monitor multiple types of risks simultaneously?

Yes, the 50T bundle not only monitors water leakage but also temperature, humidity, and smoke development, enabling comprehensive monitoring.

How does the system alert a water alarm?

Upon detecting water, the system sends real-time alerts via email, SMS (optional), or SNMP traps. Additionally, acoustic and visual alarms can be triggered.

Is the system suitable for use in smart homes?

Yes, thanks to IP technology and control options via potential-free contacts, the system can be easily integrated into smart home structures.

Basic Protection Monitoring System 50T

Basic Protection Monitoring System 50T
This cost-effective environmental monitoring system provides reliable control for sensitive areas such as data centers, industrial facilities, and telecommunications sites. It monitors parameters such as temperature, humidity, water leaks, and access to prevent failures through precise leak detection and climate monitoring. With four sensor ports, it enables flexible monitoring, two ports active by default and two more unlockable via license. Automatic sensor detection makes installation significantly easier. Thanks to Power-over-Ethernet, it only requires one cable for power and data, ideal for environments with limited outlets.

An optional cellular connection ensures communication at remote sites. The user-friendly web interface provides real-time data access and reports, while scalable architecture supports future expansions. With robust design and enhanced security features such as encryption, it is suitable for demanding environments. Real-time alerts via email or SMS ensure quick responses to critical events to maintain operational security.

DI19005 (Technical data AKCP manufacturer specifications)

Technical Specifications Didactum Monitoring System 50

ParameterDetails
Device ManagementWeb, SNMP
Sensor AccessThree-level login
LANEthernet 100 Mbit
Operating SystemLinux v.6.2
InterfaceAny browser
RAM128 MB
CPU Speed600 MHz
CPU Cores2
ClockBuilt-in clock
TimerBuilt-in watchdog
Max. Number of Sensors100 (physical sensors, dry contacts, relays)
Max. Number of Elements700 (notifications, triggers, timers, logic, sensors, etc.)
LTE Gateway ModeNo
LTE Access ModeNo
Network ProtocolsDHCP, HTTP, HTTPS, SNMP, SMTP, FTP, Syslog, TLS
Modbus RTUNo
Modbus TCPYes
VPN Secure TransmissionNo
Power Input (230V AC)No
Power Input (24–48V DC)No
Power Input (12V DC)Input
Min. Power Consumption1 W
Max. Power Consumption6 W
Analog Port4 built-in ports (6P6C for analog sensor connection)
CAN Port1 port, max 10 devices
Dry Contact Inputs2
Relay Outputs2 x 12 V, 0.25 A
USB Cameras1
IP Camerasup to 4
Operating Temperature-10 to +70 °C
Storage Temperature-25 to +85 °C
Operating Humidity0 to 90 % (non-condensing)
InstallationDesktop
Enclosure MaterialPlastic
Dimensions (L x W x H)150 x 29 x 100 mm
Weight0.5 kg

Technical Specifications Didactum Temperature Sensor

ParameterDetails
Sensor TypeAnalog sensor
MeasuresTemperature
Accuracy±0.5 °C at room temperature
Daisy ChainNo
Cable Length2 m
Power Consumption60 mW
Operating TemperatureOptimal range: -10 to +80 °C
Operating Humidity0 to 95 %
Mounting OptionsTable device, indoor, rack mounting, wall mounting
Max Distance to Unit100 m

Technical Specifications Didactum Humidity Sensor

ParameterDetails
Sensor TypeAnalog sensor
MeasuresRelative humidity
Accuracy3 % RH
Daisy ChainNo
Cable LengthRJ11 6P4C 2 m telephone cable included
Power Consumption60 mW
Operating TemperatureOptimal range: -10 to +80 °C
Operating Humidity0 to 95 % indoors
Mounting OptionsTable device, indoor, rack mounting, wall mounting
Max Distance to Unit50 m

Technical Specifications Didactum Smoke Sensor

ParameterDetails
Device TypeAnalog sensor
Sensor TypePhotoelectric
MeasuresSmoke, fire
Daisy ChainYes, up to 10 sensors in one chain. The system shows all sensors in a chain as a single element. Triggering any sensor in the chain activates the element in the web interface.
Cable LengthRJ11 / RJ12 6P4C, 2 m telephone cable included
Power Consumption100 mW
Operating TemperatureOptimal: -10 to +55 °C – Extended: -10 to +80 °C
Storage Temperature-10 to +55 °C
Operating Humidity5 to 95 % (non-condensing)
Storage Humidity5 to 95 %
Average Lifetime>= 10 years
LED DisplayRed LED
Mounting OptionsCeiling mounted
Max Distance to Unit150 m from unit or extension module

Technical Specifications Didactum Water Sensor

ParameterDetails
Sensor TypeAnalog sensor
Detection MethodCapacitive
Accuracy3 % RH
Daisy ChainNo
DescriptionSensor has two RJ connectors. RJ 6P4 connects to the analog input of the Didactum monitoring system. RJ 4P2 connects to two poles of the sensor.
Dimensions60 × 18 × 18 mm
Inputs2-wire (WDC cable)
OutputsRJ11 / RJ12
Operating Temperature-10 to +80 °C
Operating Humidity5 to 95 % (non-condensing)
Power Consumption60 mW
MountingMounting bracket included
Max Distance100 m from monitoring system
Response Time15 seconds
Recovery TimeDepends on drying speed

This website uses cookies

This website uses cookies to improve user experience. By using our website you consent to all cookies in accordance with our Cookie Policy.

Essential cookies enable basic functions and are necessary for the website to function properly.
Statistics cookies collect information anonymously. This information helps us to understand how our visitors use our website.
Marketing cookies are used by third parties or publishers to display personalized advertisements. They do this by tracking visitors across websites.