AKCP SPX8-X60: IT-Überwachung mit Schutz vor Wasserleckage und Wassereinbruch
AKCP sensorProbeX+ SPX8-X60
The AKCP sensorProbeX+ SPX8-X60 is one of the most powerful devices in professional IT and data center monitoring. Combining intelligent sensor integration, 60 dry contacts, and a robust 2U architecture, it provides a modular all-in-one solution for server room monitoring. A special focus is on reliable protection against water ingress — one of the greatest risks to any IT infrastructure.
The system is designed to inform administrators in real-time about all environmental parameters, from temperature and humidity to power supply and security. With the SPX8-X60, companies can detect physical and climatic risks early and take targeted countermeasures before damage occurs. This applies especially to water leak detection, which is often underestimated but is a critical risk factor for server room outages.
Why Water Leak Detection is so Important
Statistics show that water damage in data centers is among the most common non-technical causes of downtime. Causes vary from condensate from air conditioning units, pipe breaks in cooling systems, sprinkler leaks, to moisture from raised floors or building damage.
Even small water leaks can damage sensitive hardware or result in months of repairs. The SPX8-X60 addresses this risk with an advanced water protection concept.
Types of Water Sensors in the SPX8-X60
Point Water Sensors
These sensors monitor individual critical points such as under air conditioning units, in cable ducts, or the room's lowest point. As soon as moisture is detected, the SPX8-X60 immediately reports an event and can trigger automatic responses via dry contacts.
Leak Detection Chains
For large-area monitoring, leak detection chains are used. They are laid like cables under raised floors or along air conditioning units and detect water along their entire length. A major advantage is the localization function, which specifies the exact leak location rather than just detecting its occurrence. This saves time and costs in maintenance and planning.
Combination of Both Systems
In practice, a combination of point sensors in particularly vulnerable areas and leak detection chains under raised floors is recommended. The SPX8-X60 processes all signals in real-time and displays them in a clear web interface.
Practical Examples of Water Leak Detection
Example 1: Data Center with Raised Floor
A large data center installed a leak detection chain across the entire raised floor area. After just two weeks, the system reported a leak under an air conditioning unit. Thanks to precise location reporting, the operator immediately inspected and replaced a damaged condensate line. Without the SPX8-X60, costly damage from standing water would likely have occurred.
Example 2: Telecommunications Room
A telecommunications provider used point water sensors to monitor areas under water-bearing pipes and wall penetrations. These sensors were additionally connected to internal alarm circuits via the 60 dry contacts. Upon water ingress, IT personnel were alerted and a climate unit was automatically shut down to prevent further leaks.
Example 3: Industrial Hall with Process Cooling
In an industrial manufacturing environment, the SPX8-X60 was used to monitor cooling water lines. Using a combination of leak detection chains along the pipes and connected solenoid valves, the system could trigger an emergency shutdown immediately upon detecting a leak, preventing production downtime and costly repairs.
Integration with Security Systems
The strength of the SPX8-X60 lies not only in detecting water but also in triggering appropriate measures. Through 60 dry contact inputs, systems like fire alarms, air conditioners, or UPS units can be integrated. Outputs can switch relays and controls, such as shutting down servers upon water ingress, activating emergency pumps, or triggering audible or visual alarms.
Network Monitoring for Water Protection
Integration is SNMP-compliant, meaning water alarms can be reported via central tools like Nagios, PRTG, or check_MK — including location data and escalation management. In parallel, notifications can be sent by email with detailed damage reports, SMS via GSM modules even during network outages, and SNMP traps to network management systems.
Application Areas for Water Protection with the SPX8-X60
- Server rooms: under raised floors, cable ducts, and air conditioning units
- Data centers: full-area leak detection chains with localization
- Telecommunications facilities: monitoring sensitive switching areas
- Industrial halls: cooling water lines in production plants
- Edge and remote sites: compact integration with GSM backup
The AKCP SPX8-X60 is not only the flagship model of the sensorProbeX+ series but also sets standards in water ingress detection and leak monitoring. With high-precision sensors, scalable leak detection chains, and comprehensive dry contact integration, it offers companies the necessary security to prevent operational failures. Thanks to its modular architecture and intelligent alerting, it represents a sustainable investment for all server room and data center operators.
Can the SPX8-X60 detect small leaks early?
Yes, with point water sensors it detects even the smallest amounts of water. Due to their high sensitivity, leaks are reported before they cause damage.
What is the advantage of a leak detection chain?
A leak detection chain monitors large areas like raised floors comprehensively and reports the exact position of a leak. This significantly reduces repair time.
How is personnel notified in case of water ingress?
Alarms are immediately forwarded via email, SMS (via GSM module), or SNMP traps. In parallel, relay outputs can activate sirens or initiate emergency measures.
AKCP sensorProbeX+ SPX8-X60
SPX8-X60 (Technical data AKCP manufacturer specifications)
| Parameter | Details |
|---|---|
| Dimensions | 474.9 mm (W) x 88.4 mm (H) x 427.4 mm (D), 2U design |
| Expansion ports | EXP port for connection to EXP remote units BEB port for connection of max. 2x SPX+ BEB remote units |
| Mounting | Horizontal 2U mounting DIN rail mounting |
| Power supply | External power adapter 5.5 V / 3 A Input voltage/current: 100–240V AC, 0.22 A Options: – Power over Ethernet (PoE) – Dual 12–24 VDC internal power supply – Dual 40–60 VDC internal power supply |
| Status indicators | LED for power supply LED for network connection LED for sensor status and threshold alarms Internal buzzer for alarms |
| Components | Highly integrated, energy-efficient SMT technology for long-term reliability |
| Operating environment | Temperature: 0 °C to 70 °C (Industrial option: -25 °C to +70 °C) Humidity: 20 % to 80 % (non-condensing) |
| MTBF | 10,950,000 hours (based on field experience with sensorProbe+) |
| Base unit | 8x ports for intelligent sensors 60x dry contacts (potential-free) 1x EXP / Modbus / RS485 interface 1x BEB port 2U rack mounting with brackets |
| Max. sensor count | Maximum 150 online sensors (including expansion modules and virtual sensors) |
| SPX+ expansion modules | – 8x sensor port modules for AKCP sensors or cabinet door locks – 60x dry contact modules (3 configurations): • configurable I/O (0VDC/5VDC) • input only, 5VDC, optically isolated • isolated contact input (5–30VDC) • isolated AC detection (5–30VAC @44mA) – 4x mini relays for controlling larger relays – 4x 0–5VDC / 4–20mA inputs for third-party sensors – 2x 0–5VDC / 4–20mA inputs + 2x mini relays – valve control module |
| Optional | – internal mini UPS: 4x AA batteries – internal 40–60 VDC power supply – 4G cellular modem with external antenna – Power over Ethernet (PoE) – internal DC power supply |
| Max. users | 500 users (standard: 100 users) |
| Supported protocols | Rsyslog MQTT / MQTTS SNMP v1/v2 IPv6* RADIUS* TACACS* HTTPS Encrypted email |
| Licensing | – VPN: Connection to AKCPro Server via Ethernet or cellular network – Virtual sensor pack: 5 sensors per pack, max. 80 – Each SPX+ contains 10 free virtual sensors – Modbus/PMS: Up to 4 Modbus devices with 15 sensors each – Access control up to 500 users – IPv6 support – RADIUS user authentication – TACACS authentication via RADIUS |
| Important notes | – Max. 60 Modbus RS485 sensors (including virtual sensors and Modbus devices) – Max. 60 Modbus TCP/IP sensors (including virtual sensors and Modbus devices) * Some features require additional licenses |