AKCP securityProbe5E-X20: Sophisticated monitoring solution with protection against water ingress
AKCP securityProbe5E-X20
The AKCP securityProbe5E-X20 is a professional and advanced monitoring solution that enables companies to secure their critical IT infrastructure against a wide range of risks. Particularly in the field of water leakage monitoring and water ingress detection, this model impresses with its combination of 20 dry contact inputs, powerful sensor integration, and extended alerting functions. This makes the X20 ideal for server room monitoring, data centers, and industrial facilities – wherever just a few drops of water can cause serious outages.
With the X20 version, AKCP extends its proven 5E series and focuses on close integration of intelligent water sensors and leak detection ropes with external systems. This not only enables the detection of water damage but also allows it to be contained through automatic escalation mechanisms.
Water as an underestimated risk for data centers
Most operators think of temperature or fire protection first when it comes to monitoring. However, water is one of the greatest risks, as leaks often go unnoticed – until it is too late. Common causes include:
- Overflowing condensate tanks from air conditioning units
- Defective cooling water circuits
- Damage to sprinkler systems
- Undetected pipe bursts in raised floors
A water leakage sensor or leak detection rope connected to the securityProbe5E-X20 detects such incidents at an early stage – providing crucial time for countermeasures.
Water leakage monitoring with modular sensor integration
Up to eight RJ45 sensor ports allow connection of all intelligent AKCP sensors. For protection against water damage, the following solutions are particularly relevant:
- Spot water sensors – deployable under air conditioning units, in cable ducts, or at critical locations.
- Leak detection ropes – monitor large areas such as raised floors and, with localization, report the exact point of entry.
- Combined temperature and humidity sensors – provide early warning through rising humidity levels.
All sensors are automatically detected and brought online without manual configuration.
The role of 20 dry contacts in water protection
The outstanding feature of the 5E-X20 is the 20 dry contacts, which provide comprehensive leakage protection. These can:
- Connect additional water alarm systems
- Control solenoid valves and shut off water circuits
- Connect UPS systems or pumps
- Automatically switch off air conditioning units in case of water leakage
This means that not only is water detected, but automatic countermeasures can also be initiated to provide active protection.
Practical examples of leakage monitoring
Case 1: Raised floor in a data center
With an installed leak detection rope, an operator was able to pinpoint the exact position of a small leak. The timely alert prevented water from entering switch cabinets.
Case 2: Spot control under air conditioning units
A water leakage sensor under an air conditioning unit reported condensate leakage. The air conditioning system was immediately switched off via the dry contacts to prevent further leakage.
Case 3: Industrial environment with cooling water systems
In a manufacturing plant, leak detection ropes were combined with pumping technology. In the event of leakage, the securityProbe5E-X20 ensured that a valve closure was triggered immediately.
SNMP and Modbus integration for leakage alarms
With support for SNMP v1/v2/v3 as well as Modbus RTU and Modbus/TCP, water alarms can be forwarded to classical monitoring systems:
- Integration into Nagios, PRTG, SolarWinds, check_MK
- SNMP traps into central management platforms
- Modbus integration in industrial environments
This ensures that a triggered water alarm is not only displayed locally but also centrally logged.
Alarm management in the event of water ingress
A central aspect of water protection is alerting. The X20 can transmit alarm messages through many channels:
- E-mail with reports and status data
- SMS notification and optional voice alarms
- SNMP traps to standard systems
- Relay activation for acoustic sirens or pumps
Event filters minimize false alarms and define clear escalation levels – an advantage in leakage monitoring for large building complexes.
Video surveillance as an addition
The 5E-X20 combines water leakage monitoring with video surveillance. BNC ports allow surveillance cameras to be integrated to visually inspect raised floor areas or technical rooms. This provides technicians with immediate confirmation in case of reported leaks.
Water protection redefined
The AKCP securityProbe5E-X20 is more than just a classic monitoring system. It combines sensor monitoring, leakage early warning, escalation planning, and video surveillance in one platform. With 20 dry contacts and intelligent sensor integration, it ensures water-secure IT infrastructures – whether in server rooms, data centers, or industrial facilities.
Summary
Can the 5E-X20 detect leaks in raised floors?
Yes, with leak detection ropes the entire raised floor can be monitored and the position of water ingress displayed.
How does the system respond to water ingress?
Alarms are triggered via e-mail, SMS, SNMP traps, or dry contact signals, and pumps or air conditioning units can be automatically shut down.
Can video surveillance be combined with water sensor technology?
Yes, cameras can be used in parallel, allowing reported leaks to be visually verified in real time.
AKCP securityProbe5ESVA-X20
SEC-5ESVA-X20 (Technical data AKCP manufacturer specifications)
| Parameter | Details |
|---|---|
| Dimensions | Size: 17.08″ x 5.43″ x 1.80″ Weight: 2.6 kg |
| Expansion Ports | 2x RJ-45 expansion ports 115.2 Kbps data transfer rate Simultaneous functionality between expansion ports & RS485 port threshold status |
| Mounting | 1U rack-mount standard Rack-mount brackets included Compatible with AKCP DIN and rack-mount rails |
| Power Supply | External power supply 7.0–9 VDC, 3A Input voltage/current: 100–240V AC, 1A Optional: DCW – external ±40~60V DC input |
| Power Consumption | Typical 6.150 W, 0.82 A |
| Status Indicators | LED indicator for power supply LED for network connection LED for sensor status and threshold exceedance LED for dry contacts (status/online) |
| Components | Highly integrated low-power SMT technology for reliability CPU: AKCP i.MX25 processor 128 MB on-board NAND flash SD slot up to 16 GB |
| Operating Environment | Temperature: -35 °C to +55 °C Humidity: 20 % to 80 % (non-condensing) MTBF: 400,000 hours |
| Connectivity | Ethernet 10/100 Mbps Optional: internal 3G/4G modem |
| Inputs | 8x RJ-45 sensor ports 2x RJ-45 expansion ports 20x 2-wire dry contacts (inputs only, up to 5VDC or up to 40VDC opto-isolated via jumper) 1x USB 2.0 modem port Audio In (Analog) 2.5 mm jack Internal microphone RS485 (2-pin terminal block, Modbus) |
| Outputs | Configurable signals (0VDC/5VDC) on all 8 sensor ports Internal speaker External speaker (2.5 mm jack, analog) Mic Out, 2.5 mm jack (for modem) |
| Expansion Modules | 8-port intelligent sensors module (E-Sensor8) 16-port dry contact module (E-opto16, max. 500 sensors) Cabinet Control Unit (up to 25 per chain) Expandable up to 300 meters Modules daisy-chainable |
| Video – Analog | 4x BNC video input (externally powered) Resolution: 320×240 or 640×480 Standard: NTSC or PAL 4x PTDC controller ports |